Model NO.: NAS7006A |
Inside Dimension |
6900×3900×2700 mm(L×W×H) |
Outside Dimension |
8800x5350x3400mm(LxWxH) ( NOT including the height of air duct) |
Front Door |
3000×2600 mm(W×H), metal sheet panel door, bolt inside, strong hinge, sealing strip, 5mm glass. 3 folds color: white, blue, red, orange |
Service Door |
700×2000mm(W×H), 1 unit with 2 sets pressure lock and aluminum viewing windows |
Basement |
300mm high, full grilles with differnt models flow equalizing plate , in the middle is the standard flow equalizing plate , All around are customized flow equalizer plates |
Ramp |
2.5mm diamond plate with painting, 2pcs; 630x1800mm (WxL) |
Wall Panel |
50mm thick EPS, 950mm wide, density is 14kgs/m2. The panel with double sides 0.4mm steels, Tongue and groove interlock structure. |
Ceiling Panel |
50mm thick EPS, 950mm wide, density is 14kgs/m2. The panel with double sides 0.4mm steels, Tongue and groove interlock structure. |
Ceiling system |
Two cotton frames near the air inlet use punching technology to reduce air volume |
Intake&Exhaust System |
1x7.5kw turbo fan for air intaking, air capacity is 26000 m3/h; 1x7.5kw turbo fan for exhausting, air capacity is 26000m3/h; The frame is soldered by 50mmx50mm square tube and with powder coating. Air inlet and outlet are both with air adjusting. Air duct suitanle for 8.5m height workshop |
Lighting System |
Ceiling Lights: 8units×4pcs=32pcs×16W LED lights Illumination≥800Lux. Accessed from outside the booth and mounted behind a permanently installed glass. This will guarantee the isolation of the light and the hazardous areas and provide a flat interior surface of the booth. |
Heating System |
Italy Riello FS20 natural gas burner, 200000Kcal/h. Heat exchanger made of 1.5mm stainless steel, which features more heat dissipating surface, better heat exchange and better burner burner efficiency, max temperature: 80ºC. The burner need the Natural gas as resource to heat air and then the hot air go throught heat exchanger to the room. (Please note that we only provide the burner and its accessories. Customers need to complete the connection between the burner and the gas pipeline with the help of local electrical engineers.) |
Purification System |
Pre-filter: on the air inlet to prevent large dust and other impurities; Ceiling filter: on the ceiling frame to prevent much smaller dust, make sure the air is clean. Fiberglass floor filter: under grilles. To prevent paint mist go outside. Activated carbon filter: on air outlet. To absorb paint smell 4 kinds of flters to protect workers and environment. |
Controlling System |
spray&baking switch, time setting, lighting switch, temperature controller, power supply switch, emergency stop, breakdown alarm, etc. the temperature and the drying time are accurately shown in the control panel. It is equipped with overheat, overload protected, safe and reliable. Main electrical parts are from SCHNEIDER. |
Total Power |
16 KW ;240v,1ph ; 415v ,3ph |